Description
Split with hot water boiler from an external supplier
- Possibility of connecting to an outdoor R32 Split unit in combination with a DHW boiler from an external supplier.
- Compatible with thermostats, solar panels and boilers from other manufacturers.
- Intuitive, touchscreen controller with multi-language color screen.
- Tracking of consumed energy through a sensor controller.
- Ready to connect to photovoltaics and Smart Grid.
- 2-zone control, suitable for underfloor and radiator heating.
- SmartThings system compatible with Wi-Fi kit available as an option.
- A back-up heater is included to ensure a minimum water temperature.
- Warranty: 3 years
Outdoor unit - AE040RXEDEG/EU
Hydrobox indoor unit - AE090RNYDEG/EU
Control module - MWR-WW10N
Technical characteristics
- Nominal capacity:
- Heating A7/W35/A7/W55: 4.4/3.9 kW
- Cooling A35/W18: 5.0 kW
- Power supply (nominal):
- Heating A7/W35/A7/W55: 0.85/1.32 kW
- Cooling A35/W18: 1.09 kW
- COP (nom., heating) A7/W35: 5.20/2.95 W/W
- EER (nom., cooling) A35/W18: 4.59 W/W
- Seasonal space heating energy efficiency ηs LWT 35 °C/55 °C: 180/127 ETA%
- Seasonal heating of the premises Ef. leaving water temperature 35 °C/55 °C: A+++ / A++
- The flow:
- MCA: 16,0 A
- MFA: 20,0 A
- Leaving water temperature:
- Heating: 15~65℃
- Cooling: 5~25℃
-
Functions:
- Readiness to connect to the Smart Grid / possibility to use photovoltaics
- 3-level quiet operation mode
- 2-zone control
- Power supply (Φ, #, V, Hz): 1F, 2, 220~240 V, 50 Hz
- Backup heater capacity Default (option): 4kW
- Sound pressure (standard):
- Heating: 26 dB(A)
- Cooling: 26 dB(A)
- Sound power Heating (standard): 40 dB(A)
- Weight: 45.0 kg
- Dimensions (W x H x D): 510 x 850 x 315 mm
- Water Pipe (Inlet/Outlet): 1+1/4" Φ, inch
- Compressor: BLDC double-rotor
- Bottom Heater:-
- Sound pressure (standard):
- Heating: 44 dB(A)
- Cooling: 46 dB(A)
- Sound power Heating (standard): 58 dB(A)
- Weight: 46.5 kg
- Dimensions (W x H x D): 880 x 638 x 310 mm
- Refrigerant:
- Type: R32 (Fluorinated greenhouse gas, GWP=675)
- Factory loaded quantity:
- tCO₂e: 1,2
- 0,81 kg
-
Pipes
- Pipe connections
- liquid phase: 6.35 (1/4") Φ, mm (inch)
- gas phase: 15.88 (5/8") Φ, mm (inch)
- Length of pipe connections (outdoor/indoor unit) Max.[еквив.]: 30 m
- Elevation (indoor unit/indoor unit) Max.: 20 m
- Length without reloading: 15 Φ, mm
- Pipe connections
- Ambient temperature:
- Heating: -25~35℃
- Cooling: 10~46℃
- Domestic hot water: -25~43℃